Plastic moulded panel for covering one four breaker module on BEP Contour panels..
This BEP panel is in the same format as the BEP circuit breaker panels, but it only contains the BEP DCSM DC Systems Monitor, see 327015. 127mmW x 115mmH.
These BEP panels are in the same format as the BEP circuit breaker panels, but they only contain analog voltmeters for monitoring up to three battery banks, no breakers. 127mmW x 115mmH.
These BEP panels are in the same format as the BEP breaker panels with an analog ammeter for up to 3 battery banks, no breakers. Supplied with 1 shunt, additional shunts available if required. 127mmWx115mmH.
The BEP 900AM circuit breaker panel has 4 circuit breakers 1x5A, 2x10A, 1x15A and an analog voltmeter. Supplied with label set 1 and a 6 way negative bus bar. 127mmW x 200mmH.
The BEP901V-AM and 901V-DCSM circuit breaker panels have 12 circuit breakers 3x5A, 4x10A, 4x15A, 1x25A in square configuration and an analog voltmeter or a digital meter. Label set 1 & 6 way bus supplied, 127mmW x 295mmH
These circuit breaker panels have 12 circuit breakers 3x5A, 4x10A, 4x15A, 1x25A in square configuration and an analog voltmeter or a digital meter. Label set 1 & 6 way bus supplied, 239mmW x 200mmH
The BEP BEP 902AV-12 & 902V circuit breaker panel have 12 circuit breakers 3x5A, 4x10A, 4x15A, 1x25A in vertical configuration & an analog voltmeter or a digital meter. Supplied with label set 1 &6 way bus127mmW x 380mmH
The BEP 903-DCSM breaker panel has 20 circuit breakers 5x5A, 6x10A, 7x15A, 1x25A, 1x30A in horizontal configuration and a digital meter. Supplied with label sets 1, 2 and 3 and a 12 way negative bus bar. 351mmW x 200mmH.
These circuit breaker panels have 16 circuit breakers 4x5A, 5x10A, 5x15A, 1x20A, 1x25A in vertical configuration and meters. Supplied with label sets 1 and 2 and a 12 way negative bus bar. 239mmW x 295mmH.
These breaker panels have 24 circuit breakers 5x5A, 8x10A, 8x15A, 1x20A, 1x25A, 1x30A in square configuration and meters. Supplied with label sets 1, 2 and 3 and a 12 way negative bus bar. 351mmW x 295mmH.
This panel has 24 circuit breakers 5x5A, 8x10A, 8x15A, 1x20A, 1x25A, 1x30A in vertical configuration and a digital meter. Supplied with label sets 1, 2 and 3 and a 12 way negative bus bar. 239mmW x 380mmH.
These breaker panels have 32 circuit breakers 7x5A, 11x10A, 11x15A, 1x20A, 1x25A, 1x30A and meters. Supplied with label sets 1, 2, 3 and 4 and a 24 way negative bus bar. 463mmW x 295mmH.
This breaker panel has 28 circuit breakers 8x5A, 8x10A, 8x15A, 2x20A, 0x25A, 2x30A in a square configuration and a digital meter. Supplied with label sets 1, 2, 3 and 4 and a 24 way negative bus bar. 239mmW x 370mmH.
These circuit breaker panels have 32 circuit breakers 7x5A, 11x10A, 11x15A, 1x20A, 1x25A, 1x30A in a vertical configuration and meters. Supplied with label sets 1 to 4 and a 24 way bus bar. 239mmW x 455mmH.
This circuit breaker panel has 32 circuit breakers 7x5A, 11x10A, 11x15A, 1x20A, 1x25A, 1x30A in a horizontal configuration and meters. Supplied with label sets 1 to 4 and a 24 way bus bar. 463mmW x 295mmH.
These breaker panels have 32 circuit breakers 7x5A, 11x10A, 11x15A, 1x20A, 1x25A, 1x30A and a yacht mimic panel plus meters. Supplied with label sets 1 to 4 and 6 and a 24 way bus bar. 351mmW x 380mmH.
These breaker panels have 32 circuit breakers 7x5A, 11x10A, 11x15A, 1x20A, 1x25A, 1x30A and a launch mimic panel plus meters. Supplied with label sets 1 to 4 and 6 and a 24 way bus bar. 351mmW x 380mmH.
This circuit breaker panel has 48 breakers 12x5A, 15x10A, 15x15A, 3x20A, 1x25A, 2x30A in a vertical configuration and meters. Supplied with label sets 1 to 5 and a 2x24 way bus bars. 463mmW x 380mmH.
This circuit breaker panel has 32 breakers 7x5A, 11x10A, 11x15A, 1x20A, 1x25A, 1x30A in a square configuration and a digital meter. Supplied with label sets 1to 4 plus 6 and a 24 way negative bus bar. 351mmW x 285mmH.
ThIS breaker panel has 44 circuit breakers 10x5A, 14x10A, 14x15A, 3x20A, 1x25A, 2x30A in a vertical configuration and a digital meter. Supplied with label sets 1TO 4 PLUS 6 and a 24 way negative bus bar. 351mmW x 370mmH.
This breaker panel has 44 circuit breakers 10x5A, 14x10A, 14x15A, 3x20A, 1x25A, 2x30A in a horizontal configuration and a digital meter. Supplied with label sets 1, 2, 3, 4 and 6 and a 24 way negative bus bar. 463mmW x 285mmH.
This breaker panel has 56 circuit breakers 12x5A, 18x10A, 18x15A, 4x20A, 2x25A, 2x30A in a vertical configuration and a digital meter. Supplied with label sets 1, 2, 3, 4 and 6 and a two 24 way negative bus bars. 351mm x 455mmH.
The panels can monitor bilge pumps, freshwater pumps, engine room lights, nav light etc. Optional alarm. 12V/24V, with backlighting & label sets. 127/239mmW x 115mmH.
Label sets for BEP panels. These are the labels used for the backlight BEP Marine circuit breaker panels. Each set has 28 labels.
Blank plastic moulded panel for covering the mounting position for Matrix monitors on some BEP CB panels.
Plastic moulded panel for mounting Matrix monitors onto some BEP CB panels. Note that the aluminium backing plate of the panel must be suitedto mounting thepanel.
Screened twisted pair cable required to connect the BEP Matrix 600-DCM DC meters to their shunts. Available in 5m and 10m lengths.
Contour enclosure for mounting one large or two small ammeter shunts.
Toggle lock for BEP magnetic-hydraulic toggle CB's to prevent accidental or unintended actuation of essential circuits from either the on or the off position.
This lock slide is fitted with two adjacent double pole breakers on BEP AC panels to allow only one of the two breakers to be switched on at any time.
Drop Resistors to reduce 24V supply to 12V for the backlighting on BEP Contour panels.