11 BABBAGE ROAD
EAST ROSEVILLE
NSW 2069 AUSTRALIA
Phone: +61 (2) 9417 8455
Fax: +61 (2) 9417 8423
Catalogue
Suppliers


Buzzer KLAXON Surface Mount

KLAXON buzzer, single continuous tone, 12 or 24 V, 6mm spade terminals. Surface mount, dimensions 51 mm x 40 mm x 34mmH, offset mounting hole 6mm.

241004 Buzzer Klaxon 12V Vendor Part: 240021 $ 25.00
241005 Buzzer Klaxon 24V Vendor Part: 240022 $ 25.00

Buzzer Piezo Pulsed

Buzzer single high pitch tone (pulsed) with fly leads. Operating voltage 5 to 15V DC. Not waterproof. Dimensions d29mm x 24 mmH, base flange 41mm x 24mm, 2 mounting holes d4mm, pitch 35mm, alternatively panel mount: cutout d18mm, max panel thickness 3mm, intrusion 20mm.

241000 Buzzer piezo 5-15V pulsed w flyleads Vendor Part: S6112 $ 7.00

Buzzer Piezo Two-tone

Buzzer, dual high pitch tones (one continuous, one pulsed), 12 or 24V DC. Not waterproof. Screw terminals 2mm. Panel mount, dimensions: housing d41mm, cutout d27mm, intrusion 30mm.

241002 Buzzer piezo 6-28V two tone, spade/screw terminals Vendor Part: S6119 $ 20.00

COLE HERSEE Buzzer/Warning Lamp

COLE HERSEE single low pitch buzzer, with red warning light, above earth. Panel mount, cutout d18mm, intrusion 60mm, 3mm screw terminals.

241010 Buzzer/warning lamp COLE HERSEE 12V $ 79.00
241011 Buzzer/warning lamp COLE HERSEE 24V $ 79.00

Piezo Siren

Siren, piezo single warbling tone, 12V (polarity sensitive), surface mount on bracket, dimensions 59mm x 45mm x 50mmH. Bracket requires additional corrosion protection. Piercing sound that will wake up the dead!

241020 Siren piezo 12V $ 25.00

VDO Make Point Switch

The VDO Ocean Line make-point switch is used to trigger a signal from the sensor output for a variable resistance gauge. Dip-switch selection allows the unit to switch on rising or falling signal. Switch point setting is by dip-switches with fine adjustment by potentiometer. This unit is particularly useful where it is difficult or impossible to fit an alarm switch in addition to a gauge sensor to monitor e.g. temperature, pressure, tank level or rudder angle. The unit is fitted in series before the gauge and has the same three pin terminal input configuration as the VDO Ocean Line gauges, making fitment very easy - just unplug the three leads from the gauge, plug them into the corresponding terminals on the module, and plug the three pin output cable of the module into the gauge. The remaining two cables can be fitted directly to the warning lights in the Ocean Line gauges or used to trigger any other light and /or buzzer - maximum switching current is 300mA. Standby current <10mA, suitable for 12V or 24V.

398040 Make point switch, VDO Ocean Line 12/24V Vendor Part: X10719002037 $ 85.00
398042 Make point switch, VDO Viewline 12/24V Vendor Part: A2C59510886 $ 145.00

VDO Multifunction Alarm Switches

The VDO Multifunction alarm switches are used to trigger a signal from the sensor outputs for variable resistance gauges. These units are particularly useful where it is difficult or impossible to fit alarm switches in addition to gauge sensors to monitor e.g. temperature, pressure, tank level or rudder angle. Unlike the Ocean Line make point switch 398040, these units are fitted in parallel to the gauge. They can also be fitted to the sensors as stand-alone units, i.e. without gauges being connected. The units can be mounted in any suitable protected position using 2 screws, double sided tape or silicone adhesive, orientation is unimportant - dimensions 88 x 42mm x 29mm(h). The sensor inputs for these units can be piggy-backed off the sensor terminals on the gauges. Dip-switch selection allows the units to switch on rising or falling signals. A delay function can be selected if required. Available with single in/output (relay output, 1A max, NO) or three in/outputs i.e for three different functions (transistor outputs, 0,25A max per output, switching to negative). Both units can be used with 12V or 24V.

398045 Alarm switch multifunction 12/24V single switch Vendor Part: 410060 $ 295.00
398047 Alarm switch multifunction 12/24V triple switch Vendor Part: 410061 $ 399.00

VDO Rev Switch

The VDO speed switch is suitable for both 12V and 24V operation. It can be set to switch the negative output on rising frequency from 10Hz to 12000Hz. Variable hysteresis can be set as required. Switched output 36W max. Fit fuse to output circuit and a diode to prevent voltage spikes in parallel to any coils (e.g. relays) fitted in the output circuit. Dimensions 58mm x 42mm x 29mm.

398060 Alarm switch speed VDO 12/24V 10-12000Hz Vendor Part: 410007 $ 368.00

VDO Signal Amplifier/Dividers

The VDO Signal amplifier/dividers are used to amplify signals for tacho or speedometer inputs. The signal is boosted to a 10V square wave. They can also be used to divide the frequency of the signal. The basic unit divides by a fixed ratio of 16, alternatively there is a unit available with one selectable ratio from 1,2,4,8 or 16. Used when signals are too weak and/or the frequency is too high for the instrument to read.

398070 VDO Signal amplifier/divider (fixed ratio 16) Vendor Part: 411095 $ 170.00
398072 VDO Signal amplifier/divider (variable ratio) $ 215.00

Warning Light for VDO Oceanline Instruments

VDO Oceanline warning lamp and holder. The Oceanline gauges have a facility fit one of these warning lights, where functionally appropriate (e.g. on temperature, oil pressure, tank level gauges etc), thus obviating the need to fit a separate warning light. Appropriate switches (or sender switches) must be fitted.

398020 VDO warning light for OLB 52mm gauges 12V Vendor Part: NO5800762 $ 8.80
398021 VDO warning light for OLB 52mm gauges 24V Vendor Part: NO5800764 $ 8.80
 


back to top